MD-700 Desktop Pulse Oximeter


Desktop Pulse Oximeter MD-700 uses infrared technology instead of the traditional way of extracting blood and measuring oxygen saturation.

The COMDEK Desktop Pulse Oximeter MD-700 offers continuous and instantaneous monitoring, and provides users high level accuracy and real time response. As long as the instrument detects a single beat of pulse, it makes sound through the speaker. The speaker also provides users different tones according to different oxygen saturation. Each amount of pulse and oxygen saturation level is controllable through setting the preserved limit value. When a measured value exceeds the limit range, the alarm system will release a voice message and its LED will display with red light. This alarm system will keep working even in the mute condition. Also, COMDEK Desktop Pulse Oximeter MD-700P provides users with a comfortable operating environment through a menu list on screen. The light weight and portable design makes the COMDEK Desktop Pulse Oximeter MD-700P Pulse suitable for more extensive purposes. It is not only applicable for hospitals, but also useful for clinical surgery, ambulance systems and personal home-care applications

Additionally, even if the power is shut down on display, the preserved time and memory setting will still continue to operate using the power from batteries. The instrument will keep operating by power from built-in rechargeable batteries for around 6 hours. Furthermore, there are several sizes of optional sensors for users needs. The instrument can be compatible from neonate to adult.

SPECIFICATIONS

Measuring Range

Saturation range:
0%-100%

Pulse rate range:
30 bpm-250 bpm

Display

Oxygen saturation, pulse rate with LED display

Contrast

        - -

Sound

Volume adjustable

Memory

200hrs
12 sec. / time

Accuracy

SpO2 accuracy
¡Ó2% between 80%- 100%
Pulse accuracy
¡Ó1% of full scale

Operating Temperature

0¢XC-55¢XC
(32¢XF-131¢XF)

Power Requirement

Main supply
AC 100V/60Hz/ or 220V/50Hz
Battery
Four AA battery

Battery
Operating Time

Approx. 4 hrs

Weight

2200g

Dimension (mm)

160(W)x230(L)x140(H)



 


 